Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 490
Filtrar
1.
Eur J Cardiothorac Surg ; 65(4)2024 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-38603618

RESUMO

OBJECTIVES: Recurrence of tricuspid regurgitation (TR) after tricuspid annuloplasty can occur in cases where a dilated right ventricle exists and subsequent leaflet tethering follows. We previously reported a new technique of the right ventricular papillary muscle approximation (RV-PMA) for functional TR associated with leaflet tethering. The objective of this study is to elucidate the mid-term outcomes and evaluate the durability of RV-PMA. METHODS: Between January 2014 and March 2023, we applied RV-PMA in 20 patients of advanced functional TR with severe leaflet tethering. The indication of the technique was severe TR with leaflet tethering height >8 mm, and/or a right ventricular end-diastolic diameter >45 mm. The patients were followed up with echocardiography before discharge and at annual interval thereafter. RESULTS: There was no perioperative mortality. In the echocardiography performed before discharge, TR was decreased to mild or less in 85%, and a significant improvement in right ventricular end-diastolic diameter and tethering height were achieved (53-45 mm and 11.1-4.4 mm, respectively). Furthermore, during the median 3-year follow-up period, TR was kept controlled mild or less in 80% of the cases. CONCLUSIONS: RV-PMA is considered to be a safe, effective and durable technique as an additional approach for tricuspid annuloplasty.


Assuntos
Ventrículos do Coração , Músculos Papilares , Insuficiência da Valva Tricúspide , Humanos , Insuficiência da Valva Tricúspide/cirurgia , Músculos Papilares/cirurgia , Músculos Papilares/diagnóstico por imagem , Masculino , Feminino , Idoso , Pessoa de Meia-Idade , Ventrículos do Coração/cirurgia , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia , Resultado do Tratamento , Ecocardiografia , Anuloplastia da Valva Cardíaca/métodos , Estudos Retrospectivos , Valva Tricúspide/cirurgia , Valva Tricúspide/diagnóstico por imagem , Índice de Gravidade de Doença , Seguimentos
2.
Ann Thorac Cardiovasc Surg ; 30(1)2024 Jan 26.
Artigo em Inglês | MEDLINE | ID: mdl-37914276

RESUMO

The Y-incision technique introduced by Dr. Bo Yang in 2021 is a very innovative technique that can enlarge the aortic annulus by two or more sizes without violating the left atrium or mitral valve. However, we encountered a case in which the left coronary artery ostium was located close to the left-non commissure. Therefore, we considered it would be dangerous to expand the incision to the left coronary annulus. We therefore devised a new technique that enlarges only the noncoronary annulus in an "L" fashion instead of a "Y" fashion. In performing this surgery, preoperative three-dimensional images were useful for understanding the anatomy when planning the aortic annular enlargement procedure. The L-incision technique can be a useful alternative method of aortic annulus enlargement.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Humanos , Aorta/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Resultado do Tratamento , Anuloplastia da Valva Cardíaca/métodos , Tomografia Computadorizada por Raios X , Imageamento Tridimensional
3.
Gen Thorac Cardiovasc Surg ; 72(3): 202-205, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37882902

RESUMO

Stabilizing the aorto-ventricular junction is integral in aortic valve repair. We report our technique of internal circular suture annuloplasty. We used a continuous horizontal mattress suture of a single thick expanded polytetrafluoroethylene suture (CV-3). We put 4 stitches per sinus, so the suture was below the cusp attachment line at the nadirs and passed through the interleaflet triangle at the upper aorto-ventricular junction level. The suture was reinforced with pericardial pledgets on both sides of each commissure. We used this technique in 12 patients. The diameter of aorto-ventricular junction was reduced from 25 ± 2 mm to 22 ± 1 mm (n = 11) and was 22 ± 1 mm at the latest follow-up (4-74 months, median 41, n = 10). In 2 patients with large aorto-ventricular junction (27 mm or more), expected annular reduction was not achieved. Our modified technique is simple and seems durable. It may be useful for mild annular dilatation.


Assuntos
Insuficiência da Valva Aórtica , Anuloplastia da Valva Cardíaca , Humanos , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/cirurgia , Anuloplastia da Valva Cardíaca/métodos , Valva Tricúspide/cirurgia , Suturas , Técnicas de Sutura , Resultado do Tratamento
4.
Gen Thorac Cardiovasc Surg ; 72(3): 206-207, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37728684

RESUMO

In aortic valve repair, whilst performing a Yacoub remodelling operation, the external annuloplasty of the aortic ring plays a very important role. Here we present an adjustable external Dacron annuloplasty as an additional tool, in very selected cases, that can help surgeons to further improve their immediate results thus influencing the long-term ones.


Assuntos
Insuficiência da Valva Aórtica , Anuloplastia da Valva Cardíaca , Próteses Valvulares Cardíacas , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Polietilenotereftalatos , Insuficiência da Valva Aórtica/cirurgia , Resultado do Tratamento , Anuloplastia da Valva Cardíaca/métodos
5.
Eur J Cardiothorac Surg ; 64(6)2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-38006340

RESUMO

OBJECTIVES: The Hemispherical Aortic Annuloplasty Reconstructive Technology (HAART) ring is a rigid, internal and geometric device. The objective of this article is to assess the mid-term outcomes of aortic valve repair (AVr) using this prosthesis. METHODS: A prospectively maintained database was used to obtain outcomes for adult patients undergoing AVr using the HAART ring between September 2017 and June 2023. All aortic patients at our institution undergo life-long surveillance with regular assessment and valve imaging. RESULTS: Seventy-one patients underwent AVr using the HAART device: 53 had a trileaflet valve and 18 a bicuspid valve. The median age was 54 years, and most were male (79%). Many required concomitant intervention: 46% had a root procedure and 77% an arch repair. There were no in-hospital deaths, and the median postoperative stay was 5 days. At a mean follow-up of 3.9 (±1.1) years, freedom from reoperation was 94%. Late imaging demonstrated: zero trace (25%), 1+ (54%), 2+ (15%) and 4+ (6%) aortic insufficiency (AI). Eleven patients have ≥moderate AI under surveillance, all of whom have a trileaflet valve (21% of trileaflet patients). Four patients required reoperation: 3 for ring dehiscence and 1 for endocarditis. CONCLUSIONS: Although early results using the HAART device are encouraging, mid-term results raise concern as 21% of trileaflet patients developed recurrent ≥moderate AI by 4 years post-repair. We experienced 3 incidences of ring dehiscence requiring reoperation. Based on this, we recommend caution using the sub-annular approach for stabilization in patients with trileaflet aortic valves. Long-term results are needed to assess outcomes against established techniques.


Assuntos
Insuficiência da Valva Aórtica , Anuloplastia da Valva Cardíaca , Implante de Prótese de Valva Cardíaca , Adulto , Humanos , Masculino , Pessoa de Meia-Idade , Feminino , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Valva Mitral/cirurgia , Anuloplastia da Valva Cardíaca/métodos , Insuficiência da Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/etiologia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Reoperação , Resultado do Tratamento
6.
Am J Cardiol ; 207: 21-27, 2023 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-37722197

RESUMO

Tricuspid repair is recommended for significant functional tricuspid regurgitation (FTR) or tricuspid annulus (TA) dilation, based on TA >40 mm or >21 mm/m². The concordance between both TA dimensions related to the patient's body size has not been investigated. Patients who underwent rigid ring tricuspid annuloplasty for FTR between 2009 and 2017 were included. Assuming equality between both TA diameter criteria, patients were divided per body surface area (BSA): group 1 = BSA ≤1.9 m² and group 2 = BSA >1.9 m². The primary outcome was TR recurrence at 5 years. Tricuspid annuloplasty was performed in 186 patients (group 1: 130 patients [69.9%]; group 2: 56 patients [30.1%]). Group 1 comprised more female (70.8% to 23.2%, p <0.001) and older patients (77.1 ± 9.3 years; 74.2 ± 8.2 years, p = 0.048). Group 1 had a smaller absolute TA diameter (group 1: 45.3 ± 5.2 mm; group 2: 48.2 ± 5.6 mm, p <0.001), whereas the indexed TA size was inversely higher (group 1: 26.3 ± 3.4 mm/m²; group 2: 24.2 ± 2.7 mm/m², p <0.001). The tenting height was comparable (group 1: 7.8 ± 3.0 mm; group 2: 8.0 ± 2.7 mm, p = 0.714). The median ring size was 30 (interquartile range 28 to 32) and 32 (interquartile range 30 to 34) for groups 1 and 2, respectively (p <0.001). TR recurrence at 5 years was noticed in 20.2% and 6.5% of group 1 and 2 (p = 0.035). Indexed TA diameter (hazard ratio 1.43, 95% confidence interval 1.10 to 1.87, p = 0.008) and tenting height (hazard ratio 5.52, 95% confidence interval 1.87 to 14.57, p = 0.002) were independent predictors of TR recurrence. In conclusion, when the absolute TA diameter is used as the primary criterion, smaller patients are at a higher risk for TR recurrence by having a proportionally larger TA at the time of repair. An individualized approach guided by patient's body size might be more appropriate to indicate FTR correction to adjust for the annuloplasty sizing method.


Assuntos
Anuloplastia da Valva Cardíaca , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Humanos , Feminino , Implante de Prótese de Valva Cardíaca/métodos , Resultado do Tratamento , Anuloplastia da Valva Cardíaca/métodos , Tamanho Corporal , Estudos Retrospectivos
7.
J Cardiovasc Surg (Torino) ; 64(6): 657-667, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37486236

RESUMO

The development of tricuspid regurgitation (TR) is a common complication of mitral valve disease. Although severe TR is usually operated on at the same time of mitral valve surgery (MVS), controversies remain regarding whether mild to moderate TR patients should be operated. Concomitant tricuspid valve repair with MVS for mild-moderate TR patients. Electronic databases were searched from inception to November 20, 2022 to include any observational or randomized controlled trials (RCT) that compare concomitant tricuspid repair with MVS versus MVS alone. Mantel-Haenszel method was used to pool study estimates and calculate odds ratios (OR) with 95% confidence intervals (CI). A total of 9813 patients from 25 studies were included. Regarding primary outcomes, concomitant repair group had significantly lower 30 days mortality (OR: 0.66; 95% CI 0.45 to 0.96), all-cause mortality-based on RCTs- (OR: 0.40; 95% CI 0.22 to 0.71), cardiovascular mortality (OR: 0.53; 95% CI: 0.33 to 0.86) and heart failure hospitalizations (OR: 0.41; 95% CI: 0.26 to 0.63). However, was associated with higher permanent pacemaker implantation rates (OR: 2.09; 95% CI: 1.45 to 3.00). There were no significant differences in terms of secondary outcomes: tricuspid valve reinterventions, stroke and acute kidney injury. Furthermore, repair group showed lower risk for TR progression degrees (OR 0.08; 95% CI 0.05 to 0.16) and decreased mean of TR progression (MD -1.85; 95% CI -1.92 to -1.77). Concomitant tricuspid valve repair in mild or moderate TR at time of MVS appears to reduce not only 30 days but also long-term all-cause and cardiovascular mortality weighed against the increased risk of pacemaker implantation.


Assuntos
Anuloplastia da Valva Cardíaca , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Insuficiência da Valva Tricúspide , Humanos , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/cirurgia , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Resultado do Tratamento , Estudos Retrospectivos , Insuficiência da Valva Mitral/cirurgia , Anuloplastia da Valva Cardíaca/efeitos adversos , Anuloplastia da Valva Cardíaca/métodos
8.
Artigo em Inglês | MEDLINE | ID: mdl-37284826

RESUMO

The internal geometric ring provides full three-dimensional annular stability while minimizing the dissection of the aortic root, pulmonary artery and right ventricle and avoids reimplanting the coronaries. The external annuloplasty provides a secondary stabilization of the easily accessed fibrous portion of the annulus using the sutures for the internal annuloplasty device and minimizes the sutures above the leaflets. Together they form a complete remodelling of the ventriculo-aortic junction following its exact course. The junction together with stabilization of the subcommissural triangles defines functional aortic annulus remodelling. External annuloplasty supports the virtual basal ring.


Assuntos
Insuficiência da Valva Aórtica , Doença da Válvula Aórtica Bicúspide , Anuloplastia da Valva Cardíaca , Humanos , Insuficiência da Valva Aórtica/cirurgia , Resultado do Tratamento , Anuloplastia da Valva Cardíaca/métodos , Valva Aórtica/cirurgia
9.
Innovations (Phila) ; 18(3): 266-273, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37313738

RESUMO

OBJECTIVE: About half of tricuspid valves (TVs) have 2 posterior leaflets, and the fibrous tissue of the tricuspid annulus is poor. Considering the anatomy and histology of the TV, we devised a secure ring annuloplasty technique. We herein report the outcomes of our continuous wrapping suture annuloplasty technique using a flexible total ring. METHODS: We used a Tailor™ ring (Abbott, Chicago, IL, USA) as a full ring. The mark on the left side of the ring was fixed to the anteroseptal commissure, and the midpoint of the ring's markers was fixed at the center of the septal leaflet annulus. Using a continuous suture, all stitches were passed around the annuloplasty ring without penetration. One suture from the anteroseptal commissure ran toward the left side and another from the midpoint of the septal leaflet annulus ran toward the right, leading to annuloplasty without TV deformation. RESULTS: Eighty patients underwent TV repair with this technique. The tricuspid regurgitation (TR) score in all patients improved from 1.9 ± 0.7 to 0.8 ± 0.4 (P < 0.001) at 3 years postoperatively. The TR score of TVs with 2 posterior leaflets also improved from 1.9 ± 0.7 to 0.6 ± 0.4 after the operation and was unchanged during follow-up. The median follow-up period was 1.3 (0.5 to 2.0) years, and no patients required TV reoperation. The 3-year survival rate was 93%, and the 3-year rate of freedom from pacemaker implantation was 95%. CONCLUSIONS: The continuous wrapping suture technique using a flexible total ring is a useful procedure without TV deformation even when 2 posterior leaflets are present.


Assuntos
Anuloplastia da Valva Cardíaca , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Tricúspide , Humanos , Valva Tricúspide/cirurgia , Anuloplastia da Valva Cardíaca/métodos , Resultado do Tratamento , Fatores de Tempo , Insuficiência da Valva Tricúspide/cirurgia , Técnicas de Sutura , Suturas
10.
Eur J Cardiothorac Surg ; 63(5)2023 05 02.
Artigo em Inglês | MEDLINE | ID: mdl-37137229

RESUMO

OBJECTIVES: For patients with isolated aortic regurgitation, a double sub- and supravalvular annuloplasty has been shown to reduce recurrent aortic regurgitation after aortic valve repair compared with a single subvalvular annuloplasty. The objective of this study was to compare the geometrical and dynamic properties of single- and double-ring annuloplasties in an in vitro model. METHODS: Eighteen aortic roots from 80 kg pigs were randomized into a control, single-ring and double-ring group. Experiments were conducted in a pulsatile in vitro model. Hydrodynamics, radial force measurements at annular and sinotubular level and 2D echographic imaging were obtained. RESULTS: Both the single- and double-ring annuloplasties downsized the aortic annulus and sinotubular junction (STJ) significantly and increased the coaptation height. The double-ring annuloplasty showed an additional significant increase in coaptation height compared with the single ring [8.5 (0.9)-9.8 (0.8) mm, P < 0.01]. The single-ring annuloplasty reduced radial forces at both levels, whereas the double-ring annuloplasty showed the greatest force reduction of the STJ. CONCLUSIONS: By treating the whole functional aortic annulus, encompassing both the aortic annulus and the STJ, a greater force reduction is observed. A subvalvular annuloplasty alone is efficient in reducing aortic annulus diameter and increasing coaptation height, however, by treating the STJ as well, an additional effect is observed on coaptation height, creating a more efficient stabilization. Reduction of annular force-distensibility ratio with the double-ring annuloplasty compared with the native controls indicates a sustained stabilizing effect.


Assuntos
Insuficiência da Valva Aórtica , Procedimentos Cirúrgicos Cardíacos , Anuloplastia da Valva Cardíaca , Próteses Valvulares Cardíacas , Animais , Aorta/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/cirurgia , Anuloplastia da Valva Cardíaca/métodos , Suínos
11.
Eur J Cardiothorac Surg ; 63(6)2023 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-37040067

RESUMO

OBJECTIVES: The aim of this retrospective study was to assess the long-term results of root remodelling with tricuspid aortic valves and the effects of concomitant cusp repair and annuloplasty. METHODS: Between October 1995 and December 2021, 684 patients with root aneurysm and regurgitant tricuspid valves were treated by root remodelling. The mean age was 56.5 [standard deviation (SD): 14] years, and 538 (77.6%) were male. Relevant aortic regurgitation was present in 68.3%. Concomitant procedures were performed in 374 patients. The long-term results were analysed. The mean follow-up of 7.2 (SD: 5.3) years (median 6.6 years); it was 95% complete (4934.4 patient-years). RESULTS: Cusp prolapse was repaired in 83%, and an annuloplasty was added in 353 instances (51.6%). Hospital mortality was 2.3%, and survival was 81.7% (SD: 1.2) and 55.7% (SD: 5.8) at 10 and 20 years; age and measurement of effective height were independent predictors for death. Freedom from Aortic insufficiency (AI) II was 90.5 (SD: 1.9) at 10 years and 76.7 (SD: 4.5) at 20 years. Cusp repair of all cusps showed a lower freedom from recurrent AI ≥II at 10 years (P < 0.001). Suture annuloplasty showed a lower freedom from recurrent AI II at 10 years (P = 0.07). Freedom from reoperation was 95.5 (SD: 1.1) and 92.8 (SD: 2.8) at 10 and 20 years. The addition of an annuloplasty showed no difference (P = 0.236). Cusp repair had no effect on valve durability (P = 0.390). CONCLUSIONS: Root remodelling leads to good long-term stability. The addition of cusp repair improves the valve stability over time. The addition of suture annuloplasty improves early valve competency; it showed no effect on freedom from reoperation up to 10 years.


Assuntos
Aneurisma Aórtico , Insuficiência da Valva Aórtica , Anuloplastia da Valva Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Feminino , Valva Aórtica/cirurgia , Valva Tricúspide , Estudos Retrospectivos , Aneurisma Aórtico/cirurgia , Resultado do Tratamento , Anuloplastia da Valva Cardíaca/métodos , Insuficiência da Valva Aórtica/cirurgia , Reoperação
12.
Eur J Cardiothorac Surg ; 63(6)2023 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-36951516

RESUMO

OBJECTIVES: This study aimed to evaluate the outcomes of tricuspid annuloplasty with/without additional edge-to-edge plications in patients with functional tricuspid regurgitation (TR) and to clarify the impact of tethering on surgical outcomes. METHODS: This retrospective observational study included patients with moderate or greater functional TR who underwent initial tricuspid valve repair between January 2008 and December 2021. The patients were divided into 2 groups based on whether they had tethering (preoperative tethering area ≥0.75 cm2). All patients underwent annuloplasty, and edge-to-edge plications were added at the regurgitant leakage site identified by saline tests. The surgical outcomes of each group and the effect of tethering on recurrent moderate or greater TR were evaluated. RESULTS: One hundred and thirty-three patients were included in this study. During the follow-up period of 55.3 (standard deviation: 44.9) months, the 5-year survival rates were 78.4% in patients without tethering and 76.1% in patients with tethering (P = 0.78). The 5-year cumulative incidence rates of readmission for heart failure and recurrent TR were 10.8% and 1.3% in patients without tethering and 23.0% and 29.5% in patients with tethering, respectively (P = 0.12 and <0.001). Multivariable analyses revealed that the preoperative and predischarge tethering areas predicted recurrent TR. A large tethering area remained postoperatively in patients with tethering. CONCLUSIONS: In patients without tethering, annuloplasty and additional edge-to-edge plications are effective in avoiding recurrent TR with satisfactory midterm clinical outcomes. However, in patients with tethering, these procedures resulted in residual tethering, which could be leading to recurrent TR.


Assuntos
Anuloplastia da Valva Cardíaca , Insuficiência da Valva Tricúspide , Humanos , Valva Tricúspide/cirurgia , Valva Mitral/cirurgia , Valva Aórtica , Estudos Retrospectivos , Resultado do Tratamento , Anuloplastia da Valva Cardíaca/métodos
14.
J Thorac Cardiovasc Surg ; 165(3): 995-1006.e3, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-34049711

RESUMO

OBJECTIVES: The objectives were to analyze the long-term outcomes of tricuspid aortic valve repair for isolated severe aortic regurgitation and the impact of different annuloplasty techniques. METHODS: The study cohort consists of 127 consecutive patients who received aortic valve repair for isolated severe aortic regurgitation in the tricuspid aortic valve between 1996 and 2019 in our institution. Exclusion criteria were aorta dilatation (≥45 mm), connective tissue disease, active endocarditis, type A dissection, and rheumatic disease. Mean age of patients was 55.6 ± 16 years, and 80% were male. Median follow-up was 6.4 years. Time-to-event analysis was performed, as well as risk of death, reoperation, and aortic regurgitation recurrence. RESULTS: Cusp repair was performed in 117 patients (92%), and annuloplasty was performed in 126 patients (99%) with Cabrol stitch (73%), reimplantation technique (19.7%), or ring annuloplasty (6.3%). There was no hospital mortality. At 10 and 14 years, overall survival was 81% ± 5% and 71% ± 6%, respectively, and freedom from reoperation was 80% ± 5% and 73% ± 6%, respectively. Age and left coronary cusp repair were independent predictors of reoperation. Freedom from recurrent severe aortic regurgitation (>2+) was 73% ± 5% and 66% ± 7% at 10 and 12 years, respectively. Age, left ventricular end-diastolic diameter, and patch repair were independent predictors of recurrent aortic regurgitation. Type of annuloplasty had no impact on survival or reoperation. CONCLUSIONS: Aortic valve repair for isolated severe aortic regurgitation in the tricuspid aortic valve is a safe procedure, and durability at 14 years is acceptable. In this study, the annuloplasty technique did not influence repair durability as was found in bicuspid aortic valve repair or aortic valve-sparing surgery. Severity of cusp pathology seems to be the main determinant of repair durability.


Assuntos
Insuficiência da Valva Aórtica , Doença da Válvula Aórtica Bicúspide , Procedimentos Cirúrgicos Cardíacos , Anuloplastia da Valva Cardíaca , Humanos , Masculino , Adulto , Pessoa de Meia-Idade , Idoso , Feminino , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Valva Aórtica/patologia , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Doença da Válvula Aórtica Bicúspide/cirurgia , Aorta/cirurgia , Reoperação , Resultado do Tratamento , Anuloplastia da Valva Cardíaca/métodos , Estudos Retrospectivos
15.
Int J Cardiol ; 372: 85-90, 2023 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-36455700

RESUMO

BACKGROUND: Surgical edge-to-edge repair has been suggested for tricuspid regurgitation (TR) with complex tricuspid valve (TV) pathologies. Nevertheless, the impact of concomitant TAP has not been well established. This study aimed to compare the outcomes of tricuspid edge-to-edge repair according to the implementation of concomitant TAP. METHODS: A total of 264 patients who underwent tricuspid edge-to-edge repair between January 2001 and December 2020 were enrolled in the study, and 23 patients who had undergone previous TV repair were excluded. The remaining 241 patients were categorized into two groups: TAP (n = 190) and non-TAP (n = 51). Inverse probability of treatment weighting (IPTW) was used to adjust the baseline differences between the two groups. RESULTS: Early mortality and morbidity did not differ between the two groups. The mean follow-up duration was 111.5 ± 72.4 months. IPTW-adjusted survival analysis did not reveal a difference between the two groups in late significant tricuspid stenosis (trans-tricuspid pressure gradient ≥5 mmHg) and TV reoperations. However, freedom from overall mortality and late severe TR were significantly higher in the TAP group (p = 0.033 and 0.006, respectively). The sensitivity analysis, including propensity score matching, showed consistent results. CONCLUSION: The long-term outcomes of surgical tricuspid edge-to-edge repair were better when performed with concomitant TAP.


Assuntos
Anuloplastia da Valva Cardíaca , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Humanos , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/cirurgia , Resultado do Tratamento , Anuloplastia da Valva Cardíaca/métodos , Implante de Prótese de Valva Cardíaca/métodos , Estudos Retrospectivos , Pontuação de Propensão
16.
J Thorac Cardiovasc Surg ; 166(2): 294-303, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36404145

RESUMO

OBJECTIVE: Existing replacement options for the aortic valve have significant drawbacks, especially in children. A geometric annuloplasty ring can help to achieve consistently successful aortic valve repair, but only limited experience with use of this device has been reported in pediatric and congenital heart disease patients. METHODS: All pediatric and adult congenital patients at our institution who underwent aortic valve repair with placement of a geometric annuloplasty ring were reviewed. The study period spanned from July 2018 to April 2022. Hemodynamic outcomes were evaluated using transthoracic echocardiography. RESULTS: The study included 36 subjects. The median age was 17.4 years (range, 8-30 years). Twenty-one subjects were younger than age 18 years. The most common primary diagnoses were neoaortic valve insufficiency or neoaortic root dilation, and congenital aortic stenosis with bicuspid or functionally unicuspid aortic valve. Of the 34 subjects with procedural success, 31 (91%) had use of additional valve repair techniques and 26 (76%) had an additional concomitant procedure performed. Operative mortality was 0% (0/33), and major complication rate was 6% (2/33). The median follow-up time was 1.9 years (maximum, 3.8 years). The mean grade of aortic insufficiency was signific antly reduced after repair, with no change in mean gradients. Freedom from reoperation over the follow-up period was 97% (33/34), and freedom from ≥3+ recurrent aortic insufficiency was 94% (32/34). CONCLUSIONS: A geometric annuloplasty ring can be used to help achieve consistently successful aortic valve repair with excellent perioperative and follow-up outcomes, even in pediatric and complex congenital heart disease patients.


Assuntos
Insuficiência da Valva Aórtica , Anuloplastia da Valva Cardíaca , Cardiopatias Congênitas , Próteses Valvulares Cardíacas , Adulto , Humanos , Criança , Adolescente , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Valva Aórtica/anormalidades , Anuloplastia da Valva Cardíaca/métodos , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/cirurgia , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/cirurgia , Reoperação , Resultado do Tratamento
18.
Artigo em Inglês | MEDLINE | ID: mdl-36218304

RESUMO

We describe our approach, which is based on using an internal bicuspid annuloplasty ring not only to provide annular reduction but also to routinely achieve 180° valve symmetry. The HAART 200 ring has a circular base geometry with 180° subcommissural posts. It is sized according to the intercommissural diameter and keeps that dimension unchanged. The non-fused leaflet serves as a reference, and its free-edge length is measured with a ball sizer that predicts the required ring diameter (D): D =free-edge diameter/1.5 with transannular suturing. The ring brings the sinus-to-sinus dimension centrally to improve leaflet coaptation. More importantly, the ring remodels the fused and nonfused sinuses into equal annular segments, thereby increasing the mobility of the fused segment, facilitating its later plication. In this way, the ring establishes 180° valve geometry.


Assuntos
Insuficiência da Valva Aórtica , Doença da Válvula Aórtica Bicúspide , Anuloplastia da Valva Cardíaca , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/cirurgia , Anuloplastia da Valva Cardíaca/métodos , Humanos , Fenótipo
19.
Eur J Cardiothorac Surg ; 62(3)2022 08 03.
Artigo em Inglês | MEDLINE | ID: mdl-35916717

RESUMO

OBJECTIVES: Root reimplantation has been the favoured approach for patients with heritable aortic disorder requiring valve-sparring root replacement. In the past few years, root remodelling with annuloplasty has emerged as an alternative to root reimplantation in the general population. The aim of this study was to examine the late outcomes of patients with heritable aortic disorder undergoing valve-sparring root replacement and compare different techniques. METHODS: Using the AVIATOR registry (Aortic Valve Insufficiency and ascending aorta Aneurysm InternATiOnal Registry), data were collected from 5 North American and European centres. Patients were divided into 4 groups according to the technique of valve-sparing used (root reimplantation, root remodelling with ring annuloplasty, root remodelling with suture annuloplasty and root remodelling alone). The primary endpoints were freedom from aortic regurgitation (AR) ≥2 and freedom from reintervention on the aortic valve. Secondary endpoints were survival and changes in annular dimensions over time. RESULTS: A total of 237 patients were included in the study (reimplantation = 100, remodelling + ring annuloplasty = 76, remodelling + suture annuloplasty = 34, remodelling alone = 27). The majority of patients had Marfan syndrome (83%). Preoperative AR ≥2 was present in 41% of the patients. Operative mortality was 0.4% (n = 1). No differences were found between techniques in terms of postoperative AR ≥2 (P = 0.58), reintervention (P = 0.52) and survival (P = 0.59). Changes in aortic annulus dimension were significantly different at 10 years (P < 0.05), a difference that started to emerge 4 years after surgery. CONCLUSIONS: Overall, valve-sparring root replacement is a safe and durable procedure in patients with heritable aortic disorder. Nevertheless, root remodelling alone is associated with late annular dilatation. The addition of an annuloplasty, however, results in similar freedom from AR, reintervention, survival and changes in annulus size compared to reimplantation.


Assuntos
Insuficiência da Valva Aórtica , Anuloplastia da Valva Cardíaca , Pilotos , Aorta/cirurgia , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/cirurgia , Anuloplastia da Valva Cardíaca/métodos , Humanos , Sistema de Registros , Reoperação , Resultado do Tratamento
20.
Eur Heart J Cardiovasc Imaging ; 23(7): 979-988, 2022 06 21.
Artigo em Inglês | MEDLINE | ID: mdl-35511547

RESUMO

AIMS: Severe tricuspid regurgitation (TR) has adverse effects on outcomes, with limited therapeutic options. We report the outcomes of patients undergoing percutaneous annuloplasty as a treatment of ≥severe functional TR in a single centre. METHODS AND RESULTS: Prospective, single-arm, single-centre study that enrolled 24 consecutive patients with at least severe functional TR undergoing percutaneous annuloplasty with Cardioband system between 2019 and 2021. Clinical and echocardiographic data were prospectively collected, with a mean follow-up of 279 ± 246 days. At baseline, 66.6% were in New York Heart Association (NYHA) Classes III and IV and 100% had significant oedema. Technical success was 91.6%. At the end of follow-up, there was one death. Echocardiography showed a significant reduction in septolateral annular diameter of 10.4 mm (P < 0.001) that remained stable at the end of follow-up. The severity of the TR was also reduced. About 81.8% of patients were in NYHA Classes I and II. The number of patients with significant oedema decreased to 46% (P = 0.01). Six-minute walk distance improved by 68.8 m (P = 0.12). CONCLUSION: Percutaneous annuloplasty with Cardioband system is an effective and safe treatment for patients with symptomatic, ≥severe functional TR. Annular reduction and TR severity reduction remained significant and sustained for 1 year. Patients experienced improvements in quality of life and exercise capacity.


Assuntos
Anuloplastia da Valva Cardíaca , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Anuloplastia da Valva Cardíaca/métodos , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Estudos Prospectivos , Qualidade de Vida , Resultado do Tratamento , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/etiologia , Insuficiência da Valva Tricúspide/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...